Description
This calculation type keyword requests that a potential energy surface (PES) scan be done. A rigid PES scan is performed, which consists of single point energy evaluations over a rectangular grid involving selected internal coordinates. The molecular structure must be defined using Z-matrix coordinates. The number of steps and step size for each variable are specified on the variable definition lines, following the variable’s initial value. For example:
R1 1.41 3 0.05 A1 104.5 2 1.0 A2 120.0
This input causes variable R1 to be stepped 3 times by 0.05. Thus, four R1 values (1.41, 1.46, 1.51 and 1.56) will be done for each combination of other variables. Similarly, 3 values for A1 (104.5, 105.5 and 106.5) will be used, and A2 will be held fixed at 120.0. All in all, a total of 12 energy evaluations will be performed. Any number of variables can be stepped. The units of the step-sizes are controlled by the Units keyword and default to Angstroms and degrees.
A relaxed PES scan (with geometry optimization at each point) is requested with the Opt keyword.
If any scanning variable breaks symmetry during the calculation, then you must include NoSymm in the route section of the job, or the job will fail with an error.
Related Keywords
Examples
Output files from PES scans conclude with a table summarizing the results for the job:
Scan completed. Summary of the potential surface scan: N R A SCF ---- --------- --------- ----------- 1 0.9600 104.5000 -38.39041 2 1.0100 104.5000 -38.41306 3 1.0600 104.5000 -38.42336 4 0.9600 105.5000 -38.39172 5 1.0100 105.5000 -38.41430 6 1.0600 105.5000 -38.42453 7 0.9600 106.5000 -38.39296 8 1.0100 106.5000 -38.41547 9 1.0600 106.5000 -38.42564 10 0.9600 107.5000 -38.39412 11 1.0100 107.5000 -38.41657 12 1.0600 107.5000 -38.42668 ---- --------- --------- -----------
Chapter 6 of Exploring Chemistry with Electronic Structure Methods [Foresman15, pp.238-44,255-58] provides a detailed discussion of potential energy surface scans.
This calculation type keyword requests that a potential energy surface (PES) scan be done. A rigid PES scan is performed, which consists of single point energy evaluations over a rectangular grid involving selected internal coordinates. The molecular structure must be defined using Z-matrix coordinates. The number of steps and step size for each variable are specified on the variable definition lines, following the variable's initial value. For example:
R1 1.41 3 0.05 A1 104.5 2 1.0 A2 120.0
This input causes variable R1 to be stepped 3 times by 0.05. Thus, four R1 values (1.41, 1.46, 1.51 and 1.56) will be done for each combination of other variables. Similarly, 3 values for A1 (104.5, 105.5 and 106.5) will be used, and A2 will be held fixed at 120.0. All in all, a total of 12 energy evaluations will be performed. Any number of variables can be stepped. The units of the step-sizes are controlled by the Units keyword and default to Angstroms and degrees.
A relaxed PES scan (with geometry optimization at each point) is requested with the Opt keyword.
If any scanning variable breaks symmetry during the calculation, then you must include NoSymm in the route section of the job, or the job will fail with an error.
Output files from PES scans conclude with a table summarizing the results for the job:
Scan completed. Summary of the potential surface scan: N R A SCF ---- --------- --------- ----------- 1 0.9600 104.5000 -38.39041 2 1.0100 104.5000 -38.41306 3 1.0600 104.5000 -38.42336 4 0.9600 105.5000 -38.39172 5 1.0100 105.5000 -38.41430 6 1.0600 105.5000 -38.42453 7 0.9600 106.5000 -38.39296 8 1.0100 106.5000 -38.41547 9 1.0600 106.5000 -38.42564 10 0.9600 107.5000 -38.39412 11 1.0100 107.5000 -38.41657 12 1.0600 107.5000 -38.42668 ---- --------- --------- -----------
Chapter 6 of Exploring Chemistry with Electronic Structure Methods [Foresman15, pp.238-44,255-58] provides a detailed discussion of potential energy surface scans.